Vibrotaktil eldiven : (Record no. 200467298)

MARC details
000 -LEADER
fixed length control field 07748nam a2200445 i 4500
001 - CONTROL NUMBER
control field 200467298
003 - CONTROL NUMBER IDENTIFIER
control field TR-AnTOB
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20260210140514.0
007 - PHYSICAL DESCRIPTION FIXED FIELD--GENERAL INFORMATION
fixed length control field ta
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 171111s2025 xxu e mmmm 00| 0 eng d
035 ## - SYSTEM CONTROL NUMBER
System control number (TR-AnTOB)200467298
040 ## - CATALOGING SOURCE
Original cataloging agency TR-AnTOB
Language of cataloging eng
Description conventions rda
Transcribing agency TR-AnTOB
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title Türkçe
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number TEZ TOBB FBE BMM YL’25 KOS
100 1# - MAIN ENTRY--PERSONAL NAME
Personal name Kostakoğlu, Cengiz Sinan
Relator term author
9 (RLIN) 152445
245 10 - TITLE STATEMENT
Title Vibrotaktil eldiven :
Remainder of title yenilikçi bir duyusal rehabilitasyon cihazı /
Statement of responsibility, etc. Cengiz Sinan Kostakoğlu; thesis advisor Osman Eroğul.
246 13 - VARYING FORM OF TITLE
Title proper/short title Vibrotactile glove—a novel sensory rehabilitation device
264 #1 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE
Place of production, publication, distribution, manufacture Ankara :
Name of producer, publisher, distributor, manufacturer TOBB ETÜ Fen Bilimleri Enstitüsü,
Date of production, publication, distribution, manufacture, or copyright notice 2025.
300 ## - PHYSICAL DESCRIPTION
Extent xxiii, 123 pages :
Other physical details illustrations ;
Dimensions 29 cm
336 ## - CONTENT TYPE
Content type term text
Content type code txt
Source rdacontent
337 ## - MEDIA TYPE
Media type term unmediated
Media type code n
Source rdamedia
338 ## - CARRIER TYPE
Carrier type term volume
Carrier type code nc
Source rdacarrier
502 ## - DISSERTATION NOTE
Dissertation note Tez (Yüksek Lisans)--TOBB ETÜ Fen Bilimleri Enstitüsü Aralık 2025
520 ## - SUMMARY, ETC.
Summary, etc. Bu tez çalışmasında, felç veya üst uzuv travması sonucunda dokunma duyusunu kaybetmiş bireylerin duyusal işlevlerini yeniden kazanmalarına yardımcı olmak amacıyla yenilikçi ve giyilebilir bir rehabilitasyon sistemi (Vibrotaktil Eldiven) geliştirilmiştir. Sistem, nörosensöriyel geri bildirimi yeniden kazandırmak üzere tasarlanmış olup, titreşim tabanlı eşik altı uyarım yoluyla sinirsel plastisiteyi desteklemeyi hedeflemektedir. Cihaz, 0–1000 Hz frekans aralığında ayarlanabilir bant sınırlı beyaz gürültü titreşimleri üretir ve eldeki stratejik noktalara yerleştirilen stimülatörler aracılığıyla farklı tipteki mekanoreseptörleri —özellikle Pacinian ve Meissner cisimciklerini— uyarır. Bu uyarım yöntemi, stokastik rezonans prensibine dayanarak, düşük genlikli gürültü sinyalleriyle eşik altı duyusal potansiyelleri güçlendirir ve duyusal algı eşiğini düşürür. Böylece, merkezi sinir sisteminde yeniden düzenlenmiş duyusal bağlantıların oluşmasına katkı sağlayarak dokunsal farkındalığın artmasına olanak tanır. Sistemin donanım mimarisi; beş adet stimülatör kontrol birimi, mikrodenetleyici, güç yönetim birimi, veri depolama birimi ve veri aktarım biriminden oluşmaktadır. Bu çok bileşenli yapı düşük güç tüketimi, yüksek kararlılık ve taşınabilirlik gibi temel gereksinimleri karşılayacak biçimde optimize edilmiştir. Gömülü yazılım, Thonny Entegre Geliştirme Ortamı üzerinde MicroPython diliyle nesne tabanlı programlama prensiplerine uygun şekilde geliştirilmiş, böylece sistemin modülerliği, bakımı ve ilerideki genişletilebilirliği güvence altına alınmıştır. Gömülü yazılım mimarisi, Blueetooth Düşük Enerji hizmet yönetimi, veri işleme, terapi kontrolü ve kullanıcı etkileşimi gibi bileşenleri ayrı modüller hâlinde organize eder. Kablosuz haberleşme, Bluetooth Düşük Enerji arayüzü üzerinden sağlanmakta olup, harici olarak geliştirilen mobil uygulama aracılığıyla terapi parametrelerinin —frekans ve genlik— kişiye özel olarak ayarlanmasına imkân tanımaktadır. Bu sayede hasta, terapi yoğunluğunu kendine göre düzenleyebilmekte, klinisyen ise uygulamayı uzaktan izleyebilmektedir. Tam işlevsel bir prototip tasarlanmış, üretilmiş ve TOBB Ekonomi ve Teknoloji Üniversitesi laboratuvarlarında kapsamlı şekilde test edilmiştir. Donanım, yazılım ve mekanik bileşenlerin entegrasyonu başarıyla tamamlanmış; sistemin titreşim doğruluğu ve Blueetooth Düşük Enerji haberleşme güvenilirliği doğrulanmıştır. Cihaz, Hacettepe Üniversitesi Sağlık Bilimleri Fakültesi bünyesinde yürütülecek klinik denemelere hazır hale getirilmiş olup etik kurul onay süreci devam etmektedir. Sonuç olarak, Vibrotaktil Eldiven, üst uzuvlarda duyusal kayıp yaşayan bireyler için düşük maliyetli, taşınabilir ve bilimsel temellere dayanan yenilikçi bir rehabilitasyon çözümü sunmaktadır. Kontrollü vibrotaktil uyarım aracılığıyla nöroplastisiteyi destekleyen bu sistemin, duyusal geri kazanım sürecine ve işlevsel dokunsal geri bildirimin iyileştirilmesine klinik düzeyde anlamlı katkı sağlaması beklenmektedir.
Summary, etc. In this thesis, an innovative and wearable rehabilitation system (Vibrotactile Glove) was developed to assist individuals who have lost their sense of touch due to paralysis or upper limb trauma in regaining their sensory functions. The system is designed to restore neurosensory feedback and aims to promote neural plasticity through vibration-based subthreshold stimulation. The device generates adjustable band-limited white noise vibrations in the 0–1000 Hz frequency range and stimulates different types of mechanoreceptors—particularly Pacinian and Meissner corpuscles—via stimulators placed at strategic points on the hand. This stimulation method, based on the principle of stochastic resonance, enhances subthreshold sensory potentials using low-amplitude noise signals and reduces the sensory perception threshold. Thus, it contributes to the reorganization of sensory pathways in the central nervous system, enabling improved tactile awareness. The hardware architecture of the system consists of five stimulator control units, a microcontroller, a power management unit, a data storage unit, and a communication unit. This multi-component structure has been optimized to meet fundamental requirements such as low power consumption, high stability, and portability. The embedded software was developed using the MicroPython language within the Thonny Integrated Development Environment, adhering to object-oriented programming principles to ensure modularity, maintainability, and future scalability. The embedded software architecture organizes components such as Bluetooth Low Energy service management, data processing, therapy control, and user interaction into separate modules. Wireless communication is provided through a Bluetooth Low Energy interface, allowing therapy parameters —such as frequency and amplitude— to be customized via an externally developed mobile application. This enables the patient to adjust therapy intensity individually, while clinicians can remotely monitor the therapy process. A fully functional prototype was designed, manufactured, and thoroughly tested in the laboratories of TOBB University of Economics and Technology. The integration of hardware, software, and mechanical components was successfully completed, and the system's vibration accuracy and Bluetooth Low Energy communication reliability were validated. The device has been prepared for clinical trials to be conducted at Hacettepe University Faculty of Health Sciences, with the ethics committee approval process currently underway. In conclusion, the Vibrotactile Glove offers an innovative, low-cost, portable, and scientifically grounded rehabilitation solution for individuals with sensory loss in their upper limbs. Through controlled vibrotactile stimulation that supports neuroplasticity, this system is expected to make a clinically significant contribution to the recovery of sensory feedback and improvement of functional tactile perception.
653 ## - INDEX TERM--UNCONTROLLED
Uncontrolled term Duyu kaybı
Uncontrolled term Nöroplastisite
Uncontrolled term Stokastik rezonans
Uncontrolled term Vibrotaktil geri bildirim
Uncontrolled term Gömülü sistemler
Uncontrolled term Sensory loss
Uncontrolled term Neuroplasticity
Uncontrolled term Stohastic resonance
Uncontrolled term Vibrotactile feedback
Uncontrolled term Embedded systems
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Eroğul, Osman
9 (RLIN) 126315
710 ## - ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element TOBB Ekonomi ve Teknoloji Üniversitesi.
Subordinate unit Fen Bilimleri Enstitüsü
9 (RLIN) 77078
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type Thesis
Source of classification or shelving scheme Other/Generic Classification Scheme
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Collection code Home library Current library Shelving location Date acquired Source of acquisition Total Checkouts Full call number Barcode Date last seen Copy number Date shelved Koha item type
    Other/Generic Classification Scheme Yeni / New Ödünç Verilemez-Tez / Not For Loan-Thesis Tezler Merkez Kütüphane Merkez Kütüphane Tez Koleksiyonu / Thesis Collection 10/02/2026 Bağış / Donation   TEZ TOBB FBE BMM YL’25 KOS TZ01896 10/02/2026 1 10/02/2026 Thesis
Devinim Yazılım Eğitim Danışmanlık tarafından Koha'nın orjinal sürümü uyarlanarak geliştirilip kurulmuştur.