Difüzyon model tabanlı asimetrik dikkat mekanizmaları kullanılarak kardiyak Mr görüntü verisi arttırımı / (Record no. 200467275)

MARC details
000 -LEADER
fixed length control field 07183nam a2200445 i 4500
001 - CONTROL NUMBER
control field 200467275
003 - CONTROL NUMBER IDENTIFIER
control field TR-AnTOB
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20260206092542.0
007 - PHYSICAL DESCRIPTION FIXED FIELD--GENERAL INFORMATION
fixed length control field ta
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 171111s2025 xxu e mmmm 00| 0 eng d
035 ## - SYSTEM CONTROL NUMBER
System control number (TR-AnTOB)200467275
040 ## - CATALOGING SOURCE
Original cataloging agency TR-AnTOB
Language of cataloging eng
Description conventions rda
Transcribing agency TR-AnTOB
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title Türkçe
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number TEZ TOBB FBE BMM Ph.D’25 ÖZD
100 1# - MAIN ENTRY--PERSONAL NAME
Personal name Özdemir, Mertcan
Relator term author
9 (RLIN) 124033
245 10 - TITLE STATEMENT
Title Difüzyon model tabanlı asimetrik dikkat mekanizmaları kullanılarak kardiyak Mr görüntü verisi arttırımı /
Statement of responsibility, etc. Mertcan Özdemir; thesis advisor Osman Eroğul.
246 ## - VARYING FORM OF TITLE
Title proper/short title Diffusion model-based augmentation using asymmetric attention mechanisms for cardiac Mri images
264 #1 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE
Place of production, publication, distribution, manufacture Ankara :
Name of producer, publisher, distributor, manufacturer TOBB ETÜ Fen Bilimleri Enstitüsü,
Date of production, publication, distribution, manufacture, or copyright notice 2025.
300 ## - PHYSICAL DESCRIPTION
Extent xviii, 121 pages :
Other physical details illustrations ;
Dimensions 29 cm
336 ## - CONTENT TYPE
Content type term text
Content type code txt
Source rdacontent
337 ## - MEDIA TYPE
Media type term unmediated
Media type code n
Source rdamedia
338 ## - CARRIER TYPE
Carrier type term volume
Carrier type code nc
Source rdacarrier
502 ## - DISSERTATION NOTE
Dissertation note Tez (Doktora Tezi)--TOBB ETÜ Fen Bilimleri Enstitüsü Aralık 2025
520 ## - SUMMARY, ETC.
Summary, etc. Kardiyovasküler hastalıklar, dünya genelinde en önemli ölüm nedenlerinden birini oluşturmakta ve her yıl yaklaşık 19,8 milyon insanın hayatını kaybetmesine yol açmaktadır. Kardiyak manyetik rezonans (CMR) görüntüleme, kalp hastalıklarının tanısında altın standart olarak kabul edilmekle birlikte, derin öğrenme tabanlı tanı sistemlerinin geliştirilmesi için gerekli büyük ölçekli etiketli veri setlerinin oluşturulması, uzman etiketleme maliyetleri, etik kısıtlamalar ve nadir patolojilerin yetersiz temsili nedeniyle ciddi zorluklarla karşı karşıyadır. Bu tez, kardiyak MR görüntülemede veri yetersizliği problemini çözmek amacıyla asimetrik dikkat mekanizmalı difüzyon modeli tabanlı yeni bir bireşimsel görüntü üretim yöntemi önermektedir. Önerilen yaklaşım, Denoising Diffusion Probabilistic Model (DDPM) çerçevesini temel almakta ve UNet mimarisinde kodlayıcının son iki katmanı ile kod çözücünün ilk iki katmanına stratejik olarak yerleştirilmiş çok başlıklı öz-dikkat mekanizmalarını içermektedir. Bu asimetrik dikkat yerleşimi, hesaplama verimliliği ile anatomik yapı korunumu arasında optimal bir denge sağlamaktadır. Model, 53 sağlıklı gönüllüden elde edilen OCMR (Open Cardiac MR) veri kümesi üzerinde eğitilmiş ve 128×128 piksel çözünürlüğünde bSSFP sekans görüntüleri ile çalışılmıştır. Kapsamlı deneysel değerlendirmeler, önerilen modelin mevcut yöntemlere kıyasla üstün performans sergilediğini ortaya koymuştur. Model, 77,78 FID skoru ile VAE (325,26), WGAN-GP (235,51) ve StyleGAN2-ADA (117,70) modellerine göre anlamlı ölçüde daha iyi sonuçlar elde etmiştir. Yapısal benzerlik metrikleri açısından 0,720 SSIM ve 0,925 MS-SSIM değerleri, üretilen görüntülerin yüksek anatomik tutarlılığını doğrulamaktadır. Ablasyon çalışmaları, asimetrik dikkat yerleşiminin tekdüze dağılıma göre FID skorunda %8,8 iyileşme sağladığını göstermiştir. Üç deneyimli radyolog tarafından gerçekleştirilen klinik Turing testinde %60 doğruluk oranı elde edilmesi, bireşimsel görüntülerin gerçek görüntülerden ayırt edilmesinin zorluğunu ortaya koymuştur. Ayrıca, sol ventrikül, sağ ventrikül ve miyokard yapılarının piksel oranları ile şekil özellikleri açısından gerçek ve bireşimsel görüntüler arasında istatistiksel olarak anlamlı bir fark bulunmamıştır (p > 0,05). Bu tez, kardiyak MR görüntü sentezinde difüzyon modelleri için asimetrik dikkat mekanizması optimizasyonu konusunda özgün bir katkı sunmakta ve üretilen bireşimsel verilerin klinik uygulanabilirliğini kapsamlı bir değerlendirme çerçevesiyle ortaya koymaktadır. Sonuçlar, önerilen yaklaşımın veri artırma, gizlilik korumalı veri paylaşımı ve tıp eğitimi gibi alanlarda önemli potansiyel taşıdığını göstermektedir.
Summary, etc. Cardiovascular diseases constitute one of the leading causes of mortality worldwide, claiming approximately 19.8 million lives annually. Although cardiac magnetic resonance (CMR) imaging is considered the gold standard for diagnosing heart diseases, the development of deep learning-based diagnostic systems faces significant challenges due to expert labeling costs, ethical constraints, and inadequate representation of rare pathologies in creating large-scale labeled datasets. This thesis proposes a novel synthetic image generation method based on a diffusion model with asymmetric attention mechanisms to address the data scarcity problem in cardiac MR imaging. The proposed approach is built upon the Denoising Diffusion Probabilistic Model (DDPM) framework and incorporates multi-head self-attention mechanisms strategically placed in the last two layers of the encoder and the first two layers of the decoder within the UNet architecture. This asymmetric attention placement achieves an optimal balance between computational efficiency and anatomical structure preservation. The model was trained on the OCMR (Open Cardiac MR) dataset obtained from 53 healthy volunteers, working with bSSFP sequence images at 128×128 pixel resolution. Comprehensive experimental evaluations demonstrated that the proposed model exhibits superior performance compared to existing methods. The model achieved an FID score of 77.78, significantly outperforming VAE (325.26), WGAN-GP (235.51), and StyleGAN2-ADA (117.70). Structural similarity metrics of 0.720 SSIM and 0.925 MS-SSIM confirm the high anatomical consistency of the generated images. Ablation studies showed that the asymmetric attention placement provides an 8.8% improvement in FID score compared to uniform distribution. A clinical Turing test conducted by three experienced radiologists yielded a 60% accuracy rate, demonstrating the difficulty in distinguishing synthetic images from real ones. Furthermore, no statistically significant differences were found between real and synthetic images in terms of pixel ratios and shape features of the left ventricle, right ventricle, and myocardium structures (p > 0.05). This thesis presents an original contribution to asymmetric attention mechanism optimization for diffusion models in cardiac MR image synthesis and demonstrates the clinical applicability of the generated synthetic data through a comprehensive evaluation framework. The results indicate that the proposed approach holds significant potential in areas such as data augmentation, privacy-preserving data sharing, and medical education.
653 ## - INDEX TERM--UNCONTROLLED
Uncontrolled term Kardiyak manyetik rezonans
Uncontrolled term Difüzyon modelleri
Uncontrolled term Asimetrik dikkat mekanizması
Uncontrolled term Bireşimsel görüntü üretimi
Uncontrolled term Veri artırma
Uncontrolled term Cardiac magnetic resonance
Uncontrolled term Diffusion models
Uncontrolled term Asymmetric attention mechanism
Uncontrolled term Synthetic image generation
Uncontrolled term Data augmentation
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Eroğul, Osman
Relator term advisor
9 (RLIN) 126315
710 ## - ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element TOBB Ekonomi ve Teknoloji Üniversitesi.
Subordinate unit Fen Bilimleri Enstitüsü
9 (RLIN) 77078
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type Thesis
Source of classification or shelving scheme Other/Generic Classification Scheme
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Collection code Home library Current library Shelving location Date acquired Source of acquisition Total Checkouts Full call number Barcode Date last seen Copy number Date shelved Koha item type
    Other/Generic Classification Scheme Yeni / New Ödünç Verilemez-Tez / Not For Loan-Thesis Tezler Merkez Kütüphane Merkez Kütüphane Tez Koleksiyonu / Thesis Collection 06/02/2026 Bağış / Donation   TEZ TOBB FBE BMM Ph.D’25 ÖZD TZ01893 06/02/2026 1 06/02/2026 Thesis
Devinim Yazılım Eğitim Danışmanlık tarafından Koha'nın orjinal sürümü uyarlanarak geliştirilip kurulmuştur.